Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset the appliance if required.
(Press reset button once then release)
Allow self check to complete.
Measure the DC voltage between pin 1 on connector CN19 on the PCB to a suitable earth point.
Expected voltage approx. 120 VDC or less.