Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
Ensure NO demands
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset the appliance if required.
(Press reset button once then release)
Measure the DC Voltages between pins 1 to 5 on connector CN19 on the PCB to a suitable earth point.
The voltages should conform approximately to the table below:
Connector CN19DC Volts
Pin 1160
Pin 2 160
Pin 3148
Pin 4160
Pin 5 160