Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC voltage on the 2 pins on connector CN22.
Expect approximately 330 VDC.
Note.
Use the pins on the side of the connector when testing.
Expect approximately 330 VDC.
Note.
Use the pins on the side of the connector when testing.

Isolate as per TOPs P4
and refit as necessary