Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector from the fan assembly
Measurement:
Test 1.
Measure the resistance between the 2 outer terminals on the fan assembly.
Expected resistance approx. 53 Ohms.
Test 2.
Measure the resistance between each of the terminals on
the fan connector in turn to a suitable earth point.
Expected resistance greater than 1 MOhm on each test.
A reading of O.L is acceptable on test 2 as this is greater than 1 MOhm.
Measure the resistance between the 2 outer terminals on the fan assembly.
Expected resistance approx. 53 Ohms.
Test 2.
Measure the resistance between each of the terminals on
the fan connector in turn to a suitable earth point.
Expected resistance greater than 1 MOhm on each test.
A reading of O.L is acceptable on test 2 as this is greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary