Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the electrical connector from the diverter motor
Remove locking pin and release diverter motor
Note.
The diverter motor can be removed without the need for draining
Remove locking pin and release diverter motor
Note.
The diverter motor can be removed without the need for draining
Measurement:
Measure the resistance between the terminals on
the diverter motor, it should conform to the table below:
Note.
The test can be carried out with the diverter motor in situ.
the diverter motor, it should conform to the table below:
| Pins | Resistance | 1-2 | 6.0 KOhms or greater |
| 2-3 | 6.0 KOhms or greater |
Note.
The test can be carried out with the diverter motor in situ.

Isolate as per TOPs P4
and refit as necessary