Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Multimeter set to capacitance
Remove the connection from the pump assembly and position in the orientation shown (follow instructions on the connector)
Note:
For instructions on how to measure capacitance click on
Diagnostic + at the top of this page, select useful guides followed by
using the multimeter
Remove the connection from the pump assembly and position in the orientation shown (follow instructions on the connector)
Note:
For instructions on how to measure capacitance click on
Diagnostic + at the top of this page, select useful guides followed by
using the multimeter
Measurement:
Measure the capacitance between pins 5
and 6 on the pump harness connector.
Expected capacitance approximately 2.54 µF.
and 6 on the pump harness connector.
Expected capacitance approximately 2.54 µF.
Isolate as per TOPs P4
and refit as necessary