Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Remove fan connector and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Reset the appliance.
(Press reset button once then release)
Measure the DC voltage between pin 1 on connector CN4 on the PCB to a suitable earth point.
DC voltage should drop to approximately 55 Vdc.
(Press reset button once then release)
Measure the DC voltage between pin 1 on connector CN4 on the PCB to a suitable earth point.
DC voltage should drop to approximately 55 Vdc.

Isolate as per TOPs P4
and refit as necessary