Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect electrical connector from the spark generator
Measurement:
Test 1.
Measure the resistance between the Live and
Neutral pins on the spark generator
Test 2.
Measure the resistance between the Live pin on
the spark generator to a suitable earth connection.
Test 3.
Measure the resistance between the Neutral pin on
the spark generator to a suitable earth connection.
Expected resistance greater than 1 MOhm on all tests.
Note.
1. A reading of O.L on each test is acceptable as this is greater than 1 MOhm.
2. The pins on the spark generator should be labelled.
Measure the resistance between the Live and
Neutral pins on the spark generator
Test 2.
Measure the resistance between the Live pin on
the spark generator to a suitable earth connection.
Test 3.
Measure the resistance between the Neutral pin on
the spark generator to a suitable earth connection.
Expected resistance greater than 1 MOhm on all tests.
Note.
1. A reading of O.L on each test is acceptable as this is greater than 1 MOhm.
2. The pins on the spark generator should be labelled.

Isolate as per TOPs P4
and refit as necessary