Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn hot water tap ON with a flow rate of 3 l/min
Move connector CN8 until PCB connection strips are exposed but connector is still in contact with the PCB
Move connector CN8 until PCB connection strips are exposed but connector is still in contact with the PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between pin 2 (black) and pin 3 (grey) on the exposed strips on connector CN8 on the PCB.
Expect between 3.6 and 4.4 VDC.
Note:
The voltage may flicker on the multimeter display which is normal at a low flow rate, increasing the flow rate slightly will help stabilise the reading if desired.
Expect between 3.6 and 4.4 VDC.
Note:
The voltage may flicker on the multimeter display which is normal at a low flow rate, increasing the flow rate slightly will help stabilise the reading if desired.