Set Appliance State:
Turn Hot Water Tap On
Set appliance to 100% output
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Check the appliance gas rate with meter test dial and stop watch.
Gas rate shall be as per manufacturers specification (Refer to ADAPT for further information)
Click here for guidance on how to set appliance to 100% output
Note.
1. The appliance must burn at 100% output throughout test. If the burner modulates results will be inaccurate.
2. If the appliance is LPG, then choose option below Gas rate incorrect @ 100% output
Gas rate shall be as per manufacturers specification (Refer to ADAPT for further information)
Click here for guidance on how to set appliance to 100% output
Note.
1. The appliance must burn at 100% output throughout test. If the burner modulates results will be inaccurate.
2. If the appliance is LPG, then choose option below Gas rate incorrect @ 100% output