Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN3 from the PCB
Remove the electrical connector from the gas valve
Remove the electrical connector from the gas valve
Measurement:
Test 1.
Measure the resistance between pin 3 (brown)
and pin 4 (blue) on connector CN3.
Test 2.
Measure the resistance between pin 3 (brown) on
connector CN3 and a suitable earth connector.
Expected resistance greater than 1 MOhm for each test.
A reading of O.L is acceptable as this is greater than 1 MOhm.
Measure the resistance between pin 3 (brown)
and pin 4 (blue) on connector CN3.
Test 2.
Measure the resistance between pin 3 (brown) on
connector CN3 and a suitable earth connector.
Expected resistance greater than 1 MOhm for each test.
A reading of O.L is acceptable as this is greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary