Set Appliance State:
Mains Power Off
CH Demand
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow the burner to ignite and run with a CH demand for 1 minute.
Remove the CH demand.
Does the pump continue to run for approximately 3 minutes?
Notes.
1. This setting is adjustable in the appliance parameter settings.
If the appliance does not behave as described above, it is advisable to check Parameter 2-3-7
2. The default setting is 3 minutes.
Click here for guidance on how to access / modify the parameters.
Alternatively refer to Adapt for guidance.
Remove the CH demand.
Does the pump continue to run for approximately 3 minutes?
Notes.
1. This setting is adjustable in the appliance parameter settings.
If the appliance does not behave as described above, it is advisable to check Parameter 2-3-7
2. The default setting is 3 minutes.
Click here for guidance on how to access / modify the parameters.
Alternatively refer to Adapt for guidance.
Isolate as per TOPs P4
and refit as necessary