Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Remove locking pin and release diverter motor
Note.
The diverter motor can be removed without the need for draining

Observation:

With the aid of a torch and an inspection mirror check the position of the diverter valve pin to ensure it is not stuck down.