Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset the appliance if required.
(Press reset button once then release)
After approximately 15 seconds measure for DC voltage between
pin 9 (pink) and pin 13 (blue) on connector CN23.
Expected voltage approximately 20 Vdc.
Note.
Voltage will not be present if lockout occurs,
reset as required until test is complete.