Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Ensure NO demands
Remove connector CN14 from the main PCB and make safe
Remove connector CN14 from the main PCB and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between pin 2 and pin 3 on the
exposed strips on connector CN14 on the PCB.
Expect approximately 5Vdc.
exposed strips on connector CN14 on the PCB.
Expect approximately 5Vdc.

Isolate as per TOPs P4
and refit as necessary