Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Attach pressure gauge to gas valve pressure outlet test point
Disconnect the compensation pipe at the gas valve
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Allow the burner to ignite and establish.
1. Maximum burner pressure adjustment
Adjust nut “E” on the modureg to set the maximum gas pressure, turn the nut clockwise to increase and anti-clockwise to decrease the pressure until the required pressure is achieved (see table below).
2. Minimum burner pressure adjustment
Isolate Mains Power to appliance as per TOP's P4
Disconnect one lead to the gas valve modureg coil.
Mains power ON.