Set Appliance State:
Mains Power Off
Turn Hot Water Tap On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Activate maximum output mode (SC), CLICK HERE for guidance.
Allow burner ignite and establish.
Measure for DC voltage across the gas valve modulation coil.
Expected voltage approximately 18Vdc.
Note.
Voltage measured could be either negative or positive.
Allow burner ignite and establish.
Measure for DC voltage across the gas valve modulation coil.
Expected voltage approximately 18Vdc.
Note.
Voltage measured could be either negative or positive.