Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Gain access to PCB (use Insulation Mat as required)
Ensure NO demands are present
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance if required.
Test 1. With no demand present, measure for mains voltage across pin 2 (blue) of connector CN302 (fan neutral) and a suitable earth connection.
Is mains voltage present?
Test 2. With a hot water tap turned ON, measure for mains voltage across pin 2 (blue) of connector CN302 (fan neutral) and a suitable earth connection.
Has the mains voltage measured in test 1 dropped to approximately 0 Vac?