Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Reset appliance if required (press reset button for 2 seconds and release).
Allow boiler to commence its ignition sequence.
Measure for mains voltage between pin 6 (black) and pin 8 (blue) at CN302 on the PCB.
Approximately 5 seconds after the fan has started is mains voltage present for 7 seconds?
Note.
Appliance may enter lockout during this test, reset as required until test is complete.