Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach pressure gauge to gas valve pressure outlet test point
Disconnect the compensation pipe at the gas valve
Disconnect the compensation pipe at the gas valve
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow the burner to ignite and establish.
1. Maximum burner pressure adjustment
Adjust nut E on the modureg to set the maximum gas pressure, turn the nut clockwise to increase and anti-clockwise to decrease the pressure until the required pressure is achieved (see table below).
2. Minimum burner pressure adjustment
Disconnect one lead to the gas valve modureg coil.
Mains power ON.
1. Maximum burner pressure adjustment
Adjust nut E on the modureg to set the maximum gas pressure, turn the nut clockwise to increase and anti-clockwise to decrease the pressure until the required pressure is achieved (see table below).
2. Minimum burner pressure adjustment
| Isolate Mains Power to appliance as per TOP's P4 |
Mains power ON.
Isolate as per TOPs P4
and refit as necessary