Set Appliance State:

Gas Off
Set Multimeter to Resistance Set meter to measure resistance
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
Expose PCB by removing plastic control box cover.
Mains Isolator Switch (ON/OFF Switch) in ON position
Selector Switch in DHW Summer position
Hot Water Temperature Control set to Maximum
Remove Air Pressure Switch connector (D19-D24) from PCB
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

With fan running check short circuit resistance between terminals of air pressure switch, COM (Red/Black wire) and N.O. (White wire).
Mains power OFF and replace connector.