Set Appliance State:
Gas Off
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
Expose PCB by removing plastic control box cover.
Mains Isolator Switch (ON/OFF Switch) in ON position
Selector Switch in DHW Summer position
Hot Water Temperature Control set to Maximum
Remove Air Pressure Switch connector (D19-D24) from PCB
Expose PCB by removing plastic control box cover.
Mains Isolator Switch (ON/OFF Switch) in ON position
Selector Switch in DHW Summer position
Hot Water Temperature Control set to Maximum
Remove Air Pressure Switch connector (D19-D24) from PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
With fan running check short circuit resistance between terminals of air pressure switch, COM (Red/Black wire) and N.O. (White wire).
Mains power OFF and replace connector.
Mains power OFF and replace connector.

Isolate as per TOPs P4
and refit as necessary