Set Appliance State:
Isolate Mains Power to appliance as per TOPs P4
Mains Isolator Switch (ON/OFF Switch) in ON position
Selector Switch in DHW Summer position
Remove wires from Microswitch and make safe (1)
Mains Isolator Switch (ON/OFF Switch) in ON position
Selector Switch in DHW Summer position
Remove wires from Microswitch and make safe (1)
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Turn on DHW tap.
Measure resistance across main flow switch microswitch terminals.
Resistance measured should be short circuit across main flow switch microswitch.
Turn off DHW tap.
Measure resistance across main flow switch microswitch terminals.
Resistance measured should be open circuit across main flow switch microswitch.
Mains power OFF and replace leads.
Measure resistance across main flow switch microswitch terminals.
Resistance measured should be short circuit across main flow switch microswitch.
Turn off DHW tap.
Measure resistance across main flow switch microswitch terminals.
Resistance measured should be open circuit across main flow switch microswitch.
Mains power OFF and replace leads.

Isolate as per TOPs P4
and refit as necessary