Set Appliance State:

On/Off Switch OFF
Set Multimeter to Resistance Set meter to measure resistance
Isolate Mains Power to appliance as per TOPs P4
Remove the wires from the DHW sensor

Measurement:

Measure the resistance across the terminals of the DHW sensor.
The resistance measured will depend upon the boiler temperature, the higher the temperature the lower the resistance.
The resistance should conform to the table below.
Temperature °CResistance in kOhms
15-2015.6-14.9
20-3014.9-10.8
30-4010.8-6.0
40-506.0-4.4
50-604.4-3.0
60-703.0-2.4
70-802.4-1.6

Reconnect wires after test.