Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
Remove the DC pump connector from the PCB and make safe
Remove the DC pump connector from the PCB and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Does the Pump now run?
Note:
Do not take sound or vibration as
a sign of the pump running.
Note:
Do not take sound or vibration as
a sign of the pump running.
Isolate as per TOPs P4
and refit as necessary