Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to spark electrode
Remove connector CN6 from the PCB
Remove connector CN6 from the PCB
Measurement:
Measure the resistance between the end of the spark electrode
and a suitable Earth point.
Expected resistance greater than 1 MOhm.
and a suitable Earth point.
Expected resistance greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary