Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect the lead from the gas valve
Measurement:
Test 1:
Measure the resistance between the pins on the gas valve.
Resistances should be approximately as in the table below.
Test 2: Resistance to Earth
Measure the resistance between pin 1 and pin 2 on the gas valve.
Expected resistance greater than 1 MOhm.
Note:
The pins on the gas valve should be numbered.
Measure the resistance between the pins on the gas valve.
Resistances should be approximately as in the table below.
| Pins | Resistance | 1 - 3 | 6.7 kOhms |
| 3 - 4 | 880 ohms |
Test 2: Resistance to Earth
Measure the resistance between pin 1 and pin 2 on the gas valve.
Expected resistance greater than 1 MOhm.
Note:
The pins on the gas valve should be numbered.

Isolate as per TOPs P4
and refit as necessary