Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Selector switch set to CH/DHW position
Boiler DHW thermostat set to MAX
Attach pressure gauge to burner pressure test point
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

1. Setting the Maximum burner pressure.
Allow the burner to ignite.
Turn the outer 10mm nut (A) clockwise to increase or anti-clockwise to decrease.
Adjust maximum burner pressure to correct pressure as per table.
2. Setting the Minimum burner pressure.
Isolate Mains Power to appliance as per TOP's P4
Disconnect one wire from the modulating coil assembly (B)
Mains power On
Allow the burner to ignite.
Turn the inner red crosshead screw (C) clockwise to increase or anti-clockwise to decrease, whilst ensuring that the outer 10mm (A) nut does not move.
Adjust minimum burner pressure to correct pressure as per table.
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness