Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the leads from the gas valve modulating solenoid
Measurement:
Test 1:
Measure the resistance between the pins
on the gas valve modulating solenoid.
Expected resistance approximately 80 ohms.
Test 2: Resistance to Earth
Measure the resistance between either pin to a suitable Earth point.
Expected resistance greater than 1 MOhm.
Measure the resistance between the pins
on the gas valve modulating solenoid.
Expected resistance approximately 80 ohms.
Test 2: Resistance to Earth
Measure the resistance between either pin to a suitable Earth point.
Expected resistance greater than 1 MOhm.

Isolate as per TOPs P4
and refit as necessary