Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect CN9 from the PCB
Measurement:
Test 1:
With no hot water tap open, measure the resistance across connections 7(black) & 8(black) of connector CN9.
Expected resistance will be open circuit.
Test 2:
Open a hot water tap (minimum flow rate 2 litres/min), measure the resistance across connections 7(black) & 8(black) of connector CN9.
Expected resistance should be short circuit.
Note.
Ensure a good connection is made.
With no hot water tap open, measure the resistance across connections 7(black) & 8(black) of connector CN9.
Expected resistance will be open circuit.
Test 2:
Open a hot water tap (minimum flow rate 2 litres/min), measure the resistance across connections 7(black) & 8(black) of connector CN9.
Expected resistance should be short circuit.
Note.
Ensure a good connection is made.

Isolate as per TOPs P4
and refit as necessary