Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove leads from dhw flow switch
Dhw flow switch is located bottom right hand side of boiler
Dhw flow switch is located bottom right hand side of boiler
Measurement:
Test 1:
With no hot water tap open, measure the resistance across the connections flow switch.
Expected resistance should be open circuit.
Test 2:
Open a hot water tap (minimum flow rate 2 litres/min), measure the resistance across the connections flow switch.
Expected resistance should be short circuit.
With no hot water tap open, measure the resistance across the connections flow switch.
Expected resistance should be open circuit.
Test 2:
Open a hot water tap (minimum flow rate 2 litres/min), measure the resistance across the connections flow switch.
Expected resistance should be short circuit.

Isolate as per TOPs P4
and refit as necessary