Set Appliance State:

Set Multimeter to DC Volts Set meter to measure DC Volts
Isolate Mains Power to appliance as per TOPs P4
Gain access to PCB (use insulation mat as necessary)
Disconnect display harness from display board
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1:
Measure the voltage between terminals 3 and 4 at the PCB connector.
Voltage should be approximately 5 Vdc.
Test 2:
Measure the voltage between terminals 3 and 2 at the PCB connector.
Voltage MUST be seen to fluctuate between 3 Vdc and 5 Vdc.
Test 3:
Measure the voltage between terminals 3 and 1 at the PCB connector.
Voltage MUST be seen to fluctuate between 3 Vdc and 5 Vdc.
If the voltages on Test 2 and 3 remain static then this is incorrect.
Note:
Ensure probes do not touch together during tests.