Set Appliance State:

Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
DHW temperature control on MAX
Attach U-gauge to burner pressure test point
Remove one lead from Modureg and make safe
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Allow burner to ignite and establish.
Does the boiler operate at correct MIN pressure of 3.5mbar?
Isolate Mains Power to appliance as per TOPs P4
Reconnect lead to modureg
Mains Power On
Allow burner to ignite and establish again.
Does the boiler now operate at correct MAX pressure of 36mbar?
Click here to Set Up Burner Pressure (Ensure inlet pressure is satisfactory before attempting adjustment).
Note:
When U-gauge is removed pressure test point should be tightened & checked for gas soundness.