Set Appliance State:

Mains Power Off
Mode selector switch to Off/Reset position
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
Hot water temperature control set to maximum
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Mode selector switch to DHW position.
Allow burner to ignite and run for at least 1 minute while
measuring the voltage across the modulating solenoid terminals.
Voltage should be greater than 10 volts DC throughout operation.