Set Appliance State:

Set Multimeter to DC Volts Set meter to measure DC Volts
Isolate Mains Power to appliance as per TOPs P4
Gain access to PCB (use insulation mat as required)
Ensure no demands
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

Measure the voltage between pin 10 (grey) and pin 11 (orange) at M3 on the PCB.
Voltage should be between 0.2V and 0.5V DC.
Note:
Some or all of the pink wires on M3 may not be present depending on the exact model you are working on.