| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Instructions to set up High and Low Burner Pressures
| Isolate Mains Power to appliance as per TOP's P4 |
Turn the HW control to maximum.
Mains Power On.
Run DHW Tap and allow boiler to fire.
Rotate MAX gas pressure adjustment nut (marked A) until you
reach 9.8 mbar (rotating clockwise increases the pressure).
| Isolate Mains Power to appliance as per TOP's P4 |
Mains Power On.
Run DHW Tap and allow boiler to fire.
Adjust minimum pressure with screwdriver on minimum adjustment (Marked B)
until you have 0.8mbar (rotating clockwise decreases the pressure).
| Isolate Mains Power to appliance as per TOP's P4 |
Mains Power On.
DHW Tap On and retest Maximum Burner Pressure.
Note:
When U-gauge is removed pressure test point should be tightened & checked for gas soundness.