Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
Remove burner insulation cover
Measurement:
Confirm the spark electrode gap.
Ensure the spark gap is 3-4 mm and its position is over a burner port.
Ensure the spark gap is 3-4 mm and its position is over a burner port.
Isolate as per TOPs P4
and refit as necessary