Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
CH temperature control to max
Selector switch set to ch/dhw
Remove pump cover
Selector switch set to ch/dhw
Remove pump cover
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for mains voltage across connections brown (live) and blue (neutral) connections at the pump.
Expected voltage, mains voltage.
Expected voltage, mains voltage.

Isolate as per TOPs P4