Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to AC Volts Set meter to measure AC Volts
CH Demand
CH temperature control to max
Set selector switch to ch/dhw
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow the boiler to execute its ignition sequence and the burner to ignite.
Measure for AC voltage across the gas valve modulating coil terminals. Does the voltage measured operate between approximately 12 vac (max) and 7.0 vac (min) as the ch system heats up.