Set Appliance State:

Mode selector switch to Off/Reset position
Set Multimeter to AC Volts Set meter to measure AC Volts
Turn Hot Water Tap On
Isolate Mains Power to appliance as per TOPs P4
Hot water temperature control set to maximum
Gain access to PCB (use insulation mat as necessary)
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

Mode selector switch to DHW position.
Measure the voltage across live (brown wire) on connector M12 on the main PCB and a suitable neutral.