Set Appliance State:
Mode selector switch to Off/Reset position
| Isolate Mains Power to appliance as per TOP's P4 |
Disconnect one of the purple wires from the DHW flow switch (actuator)
Measurement:
Measure the resistance across the terminals of the DHW flow switch. Resistance should be open circuit.
Turn hot water tap On.
Measure the resistance across the terminals of the DHW flow switch. Resistance should now be closed circuit.
Reconnect wire after test.
Turn hot water tap On.
Measure the resistance across the terminals of the DHW flow switch. Resistance should now be closed circuit.
Reconnect wire after test.

Isolate as per TOPs P4
and refit as necessary