Set Appliance State:
Mains Power Off
Mode selector switch to Off/Reset position
Hot water temperature control set to maximum
Central heating temperature control set to maximum
Central heating temperature control set to maximum
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Mode selector switch to CH position.
Test 1.
Measure the voltage across brown wire on connector M11 on the main PCB and a suitable neutral.
Turn hot water tap On.
Test 2.
Measure the voltage across black wire on connector M11 on the main PCB and a suitable neutral.
Test 1.
Measure the voltage across brown wire on connector M11 on the main PCB and a suitable neutral.
Turn hot water tap On.
Test 2.
Measure the voltage across black wire on connector M11 on the main PCB and a suitable neutral.

Isolate as per TOPs P4
and refit as necessary