Set Appliance State:
Gas Off
Isolate Mains Power to appliance as per TOPs P4
Remove wires from GV1 Solenoid noting locations
Remove wires from GV1 Solenoid noting locations
Measurement:
Check resistance of GV1 Solenoid (top) is approximately 5.2 Kohms.
Note:
Replace GV1 connections after test.
Note:
Replace GV1 connections after test.

Isolate as per TOPs P4
and refit as necessary