47 094 13.
VOKERA EXCELL 80E.
TO REMOVE THE FRONT CASE.
Remove 4 screws securing the lower part of the casing to the case frame.
Slightly lift the casing and slide it gently towards the top of the appliance to disengage the case from the top suspension hooks.
Ensure the casing and screws are put to one side in a safe place.
NOTE: When carrying out tests in central heating mode the mode selector switch requires turning to the lockout/ reset position. This will ensure that the central heating time delay is overridden so that the boiler can light immediately.
Resetting the boiler after each test is not necessary in domestic hot water mode.
VOKERA EXCELL 80E.
TO REMOVE THE FRONT CASE.
Remove 4 screws securing the lower part of the casing to the case frame.
Slightly lift the casing and slide it gently towards the top of the appliance to disengage the case from the top suspension hooks.
Ensure the casing and screws are put to one side in a safe place.
NOTE: When carrying out tests in central heating mode the mode selector switch requires turning to the lockout/ reset position. This will ensure that the central heating time delay is overridden so that the boiler can light immediately.
Resetting the boiler after each test is not necessary in domestic hot water mode.
Isolate as per TOPs P4
and refit as necessary