Observation:
Temporary fault
A temporary fault is indicated by a H followed by a two digit code number (e.g. 02). This code flashes and alternates with a second two digit code (e.g. 06) that indicates the specific fault.A temporary fault prevents the boiler operating but will automatically reset once the cause of the fault has been resolved.
Click HERE if an H Code is displayed.
Permanent fault
A permanent fault 'Lock out' is indicated by an E followed by a two digit code number (e.g. 04). This code flashes and alternates with a second two digit code (e.g. 07) that indicates the specific fault.A permanent fault prevents the boiler operating and will not automatically reset. Once the fault condition has been rectified the RESET button must be pressed for 3 seconds to restart the boiler.
Click HERE if an E Code is displayed.
Do NOT hold the RESET button in for 5 seconds otherwise this will activate the de-aeration process. The boiler will run in this mode for approximately 5 minutes before restarting.