Set Appliance State:
Connect FGA to the combustion test point
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Activate chimney sweep mode.
Click here for guidance or refer to ADAPT.
(If the combustion reading is not within the specified range and the integrity of the flue system and the combustion circuit seals have been verified and the inlet gas pressure have been verified, then it will be necessary to adjust the combustion rate of the appliance).
Adjust gas valve (CO/CO2 ratio) to the manufacturers specified values, refer to ADAPT for guidance / procedure.
Has it been possible to adjust the combustion readings to within the manufacturers specified range?
Click here for guidance or refer to ADAPT.
(If the combustion reading is not within the specified range and the integrity of the flue system and the combustion circuit seals have been verified and the inlet gas pressure have been verified, then it will be necessary to adjust the combustion rate of the appliance).
Adjust gas valve (CO/CO2 ratio) to the manufacturers specified values, refer to ADAPT for guidance / procedure.
Has it been possible to adjust the combustion readings to within the manufacturers specified range?