Adjust, Service, Repair or Replace as necessary
Isolate Mains Power to appliance as per TOPs P4
Isolate Water and Gas as appropriate

Location:
The boiler pump will operate if the system temperature drops below 7°C. If the temperature falls to 4°C the burner will ignite and remain lit until the temperature reaches 10°C. At this temperature the burner will extinguish but the pump will continue to operate for 15 minutes. This feature will protect the boiler and to some extent adjacent parts of the system but additional devices must be incorporated to guarantee frost protection.
Upon completion of the fault diagnostics carry out final electrical safety tests and checks as per TOPs (C6).

Refer to ADAPT for further information.