Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Remove the actuator head from the diverter valve

Observation:

Push on the pin in the diverter valve body with a screwdriver or similar. The pin should move easily in and out with a little resistance from the diverters spring.
Expected movement approx 8mm.