Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove integral clock from appliance
Measurement:
Measure the resistance between terminals 1 and 2 of the clock.
If a MECHANICAL timer is fitted resistance should be approximately 69kOhms.
If an ELECTRONIC timer is fitted resistance should be greater than 1M Ohm.
If a MECHANICAL timer is fitted resistance should be approximately 69kOhms.
If an ELECTRONIC timer is fitted resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary