Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the actuator head from the diverter valve
Observation:
Push on the pin in the diverter valve body with a screwdriver or similar. The pin should move easily in and out with a little resistance from the diverters spring.
Expected movement approx 8mm.
Expected movement approx 8mm.
Isolate as per TOPs P4
and refit as necessary