Observation:
Some versions of the Ecoblue range may be compatible with low voltage / eBus controls.
There are many different types of control available and even after consultation with Baxi
it was not possible to provide precise fault finding for all the types of control available.
F83 indicates there is a problem with the communication between the boiler PCB
and the receiver unit (wireless controls) or the room thermostat (wired controls).
F85 indicates a problem with the signal between the
receiver unit and the room thermostat (wireless controls).
Confirm the satisfactory operation of the control installed, ensuring the wireless
link is correctly established where applicable and that the wiring to the receiver or
room thermostat is satisfactory (Refer to the specific control manual for guidance).
Is both the operation of the controls and the wiring to them satisfactory?